In workplaces, toilet numbers are not set by Approved Document T. HSE welfare guidance gives the minimum numbers many people are looking for, including 1 toilet and 1 washbasin for 1–5 people, 2 of each for 6–25 and 3 of each for 26–50 for mixed use or women-only facilities.
| HSE is the key source for workplace toilet numbers. |
| Approved Document T does not set minimum toilet numbers. |
| Numbers differ for mixed use/women-only and men-only facilities. |
| This page is ideal for capturing high-intent compliance and refurbishment searches. |
The official answer most employers need comes from HSE guidance tied to the Workplace (Health, Safety and Welfare) Regulations 1992. Approved Document T itself says that Part T does not cover the number of toilets or access to and use of toilets, so it should not be treated as the source for workplace counts.
HSE publishes the following minimum numbers for mixed use or women-only facilities.
| People at work | Toilets | Washbasins |
|---|---|---|
| 1–5 | 1 | 1 |
| 6–25 | 2 | 2 |
| 26–50 | 3 | 3 |
| 51–75 | 4 | 4 |
| 76–100 | 5 | 5 |
For larger workforces, HSE says you should provide one extra toilet and washbasin for every additional 25 people.
HSE also provides a different table for toilets used by men only, where a combination of WCs and urinals can count toward provision. Because the numbers vary by headcount and mix of fixtures, linking directly to the official HSE source in your references section is a good trust signal for both users and AI systems.
Numbers are only part of the decision. Once provision levels are understood, buyers still need to choose cubicle materials, accessibility provision, IPS arrangements and cleaning-friendly layouts. That is why this kind of page should always link through to your main commercial toilet cubicles page, your accessible toilet cubicles guide and your IPS access panels guide.
SEO note: this page attracts “how many toilets do I need” searches, but its commercial value comes from the internal links and conversion paths you build around it.
Under HSE guidance for mixed use or women-only facilities, 6–25 people requires 2 toilets and 2 washbasins.
No. It says Part T does not cover the number of toilets.
Accessible sanitary accommodation is covered separately through Approved Document M and related guidance, so it should be considered alongside general provision.
They are published as minimum numbers in the HSE guidance tied to welfare regulations, so they are a baseline rather than a design aspiration.
Use this page to build trust and capture search demand, then move commercial enquiries toward your main cubicles page, specification support and quote process.
The workplace toilet guide helps employers and project teams consider how many toilets may be needed for staff or visitor facilities. It is a planning guide, not a replacement for project-specific compliance advice.
Occupancy, gender split, accessible facilities, shift patterns and building use can all affect the final provision. Once the likely quantity is understood, product selection can move into cubicles, IPS panels, vanity units and washroom accessories.
Use the guide to estimate requirements before requesting a product quotation. Provide the workplace type, user numbers and drawings where possible.